product number | Control mode | Specifications | Working pressure | Characteristic | |||||
A4FM | DR,FR | 16,22,28,40,71,125,250,500,series1,3 | Nominal pressure:40MPa, peak pressure: 45MPa . | A4FM Axial Piston Quantitative Motor with Swashplate Structure for Hydraulic Driving in Open Loop Flow is proportional to driving speed and displacement. Excellent oil absorption performance Very low noise - Long service life - Allow the use of combined motors - Axle drive for assembling other motors | |||||
DRG,EO | |||||||||
LR,MA | |||||||||
EM,HD | |||||||||
HS,DS | |||||||||
HW-Hydraulic Control, Mechanical Servo | |||||||||
Safety instructions: | |||||||||
1,During start-up and operation, the pump shell must be filled with hydraulic oil (injected into the shell cavity). It must be started at low speed without load until the system is completely emptied. | 2,When parked for a long time, the oil can be discharged from the shell through the working pipeline. When restarting, enough oil should be injected into the shell. | 3,The minimum oil suction pressure of the nozzle S shall not be reduced to less than 0.8 bar. Installation location | 4,The axis is horizontal to the bottom. When mounting on the tank, the installation position of "axis level, suction port facing bottom" is not allowed. | ||||||
5,Pump position below minimum oil level in tank (standard) | 6,Fill the axial plunger pump before starting through the highest position of the shell outlet. | ||||||||
Suggestion: | |||||||||
1,Filling suction pipeline | 2,Low-speed motor (ignition speed) until the motor system is fully filled | 3,The lowest immersion depth of suction or drain pipelines in the tank is 200 mm (relative to the lowest oil level in the tank). Installation position higher than tank level | 4,A motor mounted at a position higher than the lowest oil level of the tank Installation position below tank level | ||||||
5,It is not allowed to use the installation position of "shaft against the top" and "axis level, oil suction port at the bottom" (when shutdown, the pump shell discharges oil through oil suction pipeline). | |||||||||
Note: | |||||||||
1, Maximum permissible pipette length Hmax = 800 mm | 2,Minimum Permissible Pressure of Oil Nozzle S (Minimum Oil Absorption Pressure) |